R22 subcooling chart - FIGURE 1: This chart serves as a quick reference guide to technicians who are troubleshooting cooling systems. ... Subcooling is the same temperature difference on the high side. “In the example given earlier, suction pressure of 118 psi converts to a saturated temperature of 40°. If the suction gas is 50°, then there is 10° of superheat ...

 
Jan 21, 2020 · Generally, you will see normal superheat (8°-14°) on a system with heat mode TXV, and the subcooling will generally be a bit higher than usual, especially when measured outside. Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system. . Kp.connect

Measuring Subcooling for R22 Required Tools. Now, let’s talk about measuring subcooling. You’ll need a few tools for this task, such as a digital thermometer, pressure gauge, and a pressure-temperature chart for R22. These tools will help you gather accurate data to calculate subcooling levels. Step-by-Step Process. Attach pressure gaugeHere is a table with these causes that will help us understand why we get low superheat normal subcooling: Low Superheat Causes: Non-Normal Subcooling Causes (High Or Low): Indoor airflow (CFMs) is too low. Oversized AC unit. Outdoor airflow is too low (or condenser coils heat exchange is impeded). High refrigerant charge (overcharged AC unit).a refrigerating system, exclusive of any subcooling or superheating. This term usually describes condensation or evaporation of a zeotrope. ODP – ozone depletion potential – degree to which a substance can degrade the ozone layer; all measurements relative to a similar mass of CFC-11, which is indexed to 1.0.All piston dimensionsSubcooling r410a system temp split air hvac chart low designed pressures condenser significance pm vbb talk Carrier air compressor conditioner 06e refrigeration price r22Designed subcooling. Piston ring repair fig guide specificationsR410a charging chart R22 chart hvac system sorry keep cut phone side …Have you ever wanted to create a flow chart in PowerPoint but didn’t know where to start? Look no further. In this step-by-step guide, we will walk you through the process of creat... How to refill refrigerant in a home AC or air conditioner. In this video I recharge a R22 unit with refrigerant using the subcooling method. I show the recha... 17 Jun 2016 ... ... Chart in order to find our Target Superheat ... Exactly What is Superheat and Subcooling? Shown on ... How To Refill R22 AC With Subcooling Method.Here’s the step-by-step guide: Prior to subcooling measurement, the AC unit should be off for at least 30 minutes. This will equalize the refrigerant pressure throughout the unit (lines, coils) since the refrigerant is in a saturated state (mixture of vapor and liquid). Let the air out of the HVAC gauge. Open the vent, listen to that ...When it comes to mailing letters and packages, it is important to know how much postage you need in order to ensure that your mail reaches its destination. One of the best ways to ...We use a manifold gauge to measure superheat (blue gauge; low side) and subcooling (red gauge; high side). This gauge can be used to measure superheat and …The superheat chart includes target AC superheat for 55°F to 128°F outdoor temperature (DB temperature) and for 50°F to 76°F indoor evaporator temperature (WB temperature). You will find the chart that summarizes all total superheats further on.Description. The model ASX14 superheat and subcooling accessory head measures refrigerant pressure and temperature simultaneously. It then calculates and displays superheat or subcooling. It has a 1/4” industry standard fitting for actual pressure. A pipe clamp thermocouple is included for temperature. Select R22 or R410A.What should my Subcooling and Superheat be? For subcooling a ballpark range may be somewhere inbetween 10-15 degrees F. For superheat it could be 12-20 degrees F. Check with the manufacturer though. Many units have a charging chart, behind the name plate on the condensing unit, use this first.HVAC App to Calculate Subcooling. Our Pressure Temperature Chart for the selected refrigerant is available for quick access; just use the button labeled (P/T). Use the refrigerant drop down for access to over 100 refrigerants. Plus and minus buttons add and subtract values in intervals of 1 to their related input fields.*Red Italics Indicate Inches of Mercury Below Atmospheric Pressure Saturation Pressure-Temperature Data for R407C (psig)*With a manifold gauge (and via R-22 PT chart), we measure the saturated refrigerant temperature of 89°F. The clamp-on thermometer reads 77°F. Here is how we use the …Subcooling Charging Method - TXV (Expansion Valve) R410A & R22 Step 3 – subtract required subcooling (Step 1) from converted temperature (Step2) – This is the required liquid line temperature. Step 4 – Measure liquid line temperature. ... Superheat Charging Chart - Cooling - non-TXV - R410A & R22 www.hvacsalesandsupply.com. Title ...Up to 10% lower capacity. Lubricant Recommendation: Compatible with mineral and alkylbenzene oil and if oil return becomes a concern, addition of polyolester lubricant in 5% increments could help resolve the issue. Retrofitting to: R-422B for R-22 Air Conditioning page 95. R-422B for R-22 Refrigeration page 95.Apr 8, 2020. 7 min read. The HVAC Subcooling Charging Method, Explained! Updated: Nov 20, 2023. In this article, we will define subcooling, calculate subcooling, explain …Superheat Charging Chart Cooling nonTXV R410A & R22. Preview. 8 hours ago Subcooling Charging Method - TXV (Expansion Valve) R410A & R22 Step 3 – subtract required subcooling (Step 1) from converted temperature (Step2) – This is the required liquid line temperature. Step 4 – Measure liquid line temperature.In this HVAC Video, I go over what Subcooling to set an Air Conditioning System to if the rating plate is worn off. I also go over how to figure out what ref...Most of you know R-32 as a necessary component in the widely popular HFC blend known as R-410A Puron. R-32 along with R-125 gets you that R-410A that is found in nearly every air conditioner today. However, in recent years there has been a push to slowly phase down R-410A. That is because of 410A’s very high Global Warming … HVAC App to Calculate Superheat. Our Pressure Temperature Chart for the selected refrigerant is available for quick access; just use the button labeled (P/T). Use the refrigerant drop down for access to over 100 refrigerants. Plus and minus buttons add and subtract values in intervals of 1 to their related input fields. SuperCool Slide Rule. $19.99. Quantity. Add to Cart. PRODUCT INFO. SuperCool Slide Rule - R22 & R410a Charging & Duct Calculator - Air Conditioning and HVAC Troubleshooting, A/C Educational Products, & AC Charts - SuperHeat & SubCooling. HVAC App to Calculate Subcooling. Our Pressure Temperature Chart for the selected refrigerant is available for quick access; just use the button labeled (P/T). Use the refrigerant drop down for access to over 100 refrigerants. Plus and minus buttons add and subtract values in intervals of 1 to their related input fields. Subcooling is beneficial because it prevents the liquid refrigerant from changing to a gas before it gets to the evaporator. Pressure drops in the liquid piping and vertical risers can reduce the refrigerant pressure to the point where it will boil or "flash" in the liquid line. This change of phase causes the refrigerant to absorb heat before ...Don't be fooled by an abridged chart with missing information, tidbits of random formulas and rule of thumb calculations all crammed on to one chart. The HVAC 3-Pack comes with 3 charts. One for sizing ductwork, one for calculating superheat/subcooling on R-22 systems and one for calculating superheat/subcooling on R-410a systems.Up to 10% lower capacity. Lubricant Recommendation: Compatible with mineral and alkylbenzene oil and if oil return becomes a concern, addition of polyolester lubricant in 5% increments could help resolve the issue. Retrofitting to: R-422B for R-22 Air Conditioning page 95. R-422B for R-22 Refrigeration page 95.R-422B APPLICATIONS: u Residential Air Conditioning u Commercial Air Conditioning PERFORMANCE: u Best match at warmer evaporator temps / AC u Lower discharge temperature than R-22 u Slightly lower capacity than R-22 u No oil change required Non-Ozone Depleting / Nonflammable / Non-toxic AVAILABLE SIZES Type Size Cylinder 25 …How to check, measure, and read superheat and subcooling on a central air conditioner unit. In this video I do not go into the details of superheat and subco...R22 chart superheat charging temperature curves line orifice system split liquid subcooling r410a cooling tables compressor txv metering device yorkEffect of subcooling on r22 mass flow rate. fig. 20 – effect of Chart r22 superheat subcooling charging amazon calculatorR22 & r410a superheat subcooling charging chart duct …TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced …Units manufactured after 7/09 used this subcooling chart. Check out the 036 unit at 12 SC. Then Lennox updated the chart with this update on 5/13. Somehow a 036 unit goes from 12 SC to 4 SC without any changes to the product. So I am charging a 13ACX-036 per the new label at 4 SC.HVAC Chart 3 Pack, R-22 Superheat Subcooling Calculator, R-410a Superheat Subcooling Calculator and Duct Calculator. 4.6 out of 5 stars ... Laminated / PT Chart; R22 / R410A; These HVAC tools are used for assistance in sizing ductwork for HVAC systems. Replaces / Supersedes: PTCHART PT CHART Pressure Chart …Here is a table with these causes that will help us understand why we get low superheat normal subcooling: Low Superheat Causes: Non-Normal Subcooling Causes (High Or Low): Indoor airflow (CFMs) is too low. Oversized AC unit. Outdoor airflow is too low (or condenser coils heat exchange is impeded). High refrigerant charge (overcharged AC unit). 145 °F. 571.7 psig. 150 °F. 607.6 psig. 155 °F. 645.2 psig. You can see that this R410A pressure chart includes high and low side pressures at temperatures ranging from -60 °F to 155 °F. Higher temperature equates to higher pressure. Here are 4 examples of how you can use this chart: Robo stated it clear, the normal superheat for a residential system can and will vary and some charts go even further than he stated 2-45 degrees. That answer above drives the point, if you do not know the evaporator load, you can not predict the superheat. Reply. 06-02-2011, 06:58 PM #14. hvacvegas.R-22 Superheat Calculation (#1 Example) R-410A Superheat Calculation (#2 Example) R-134A Superheat Calculation (#3 Example) Related posts: Superheat Formula. This is …-40-39-38-37-36-34-33-32-31-30-29-28-27-26-24-23-22-21-20-19-18-17-16-14-13-12-11-10-9-8-7-6-4-3-2-1: 0: 1: 2: 3: 4: 6: 7: 8: 9: 10: 11: 12: 13: 14: 16: 17: 18: 19 ...Find great deals on eBay for r22 superheat subcooling chart. Shop with confidence. Skip to main content. Shop by category. Shop by category. Enter your search keyword ... PT Chart R22 R-410A Laminated Pocket Aid Pressure / Temperature # 34-3400-02. Opens in a new window or tab. Brand New. C $10.11. Top Rated Seller Top Rated Seller.The photo shows both sides of the tool. This tool is made of thick durable water resistant paper stock with corner rivets. It fits easily in your shirt pocket at approximately 6.25 inches high by 3.25 inches wide. Shop Amazon for R22 Superheat Subcooling Calculator Charging Chart and find millions of items, delivered faster than ever.According to the R-22 PT chart, this is equal to about 54°F. With the thermometer, we measured the saturated R-22 temperature of 45°F. Here is how we can calculate the R-22 superheat in this system: Superheat (R-22) = 54°F – 45°F = 9°F. The superheat calculator also gives us 9°F superheat for R-22 refrigerant. What should my Subcooling and Superheat be? For subcooling a ballpark range may be somewhere inbetween 10-15 degrees F. For superheat it could be 12-20 degrees F. Check with the manufacturer though. Many units have a charging chart, behind the name plate on the condensing unit, use this first. How To Calculate Subcooling? Formula, Subcooling Calculator (R22, 410A, etc.) · Subcooling Formula. We only need to subtract the subcooled liquid refrigerant ...STEP 2 - Remove the pressure tap cap and valve cores from both service valves. STEP 3 - Purge the refrigerant lines and indoor coil with dry nitrogen. STEP 4 - Wrap a wet rag around the valve body to avoid heat damage and continue the dry nitro-gen purge. Braze the refrigerant lines to the service valves.For detailed charging instructions see installation instructions provided with unit. Measure air temperature to outdoor coil for cooling and indoor coil for heating. Place and "X" on the appropriate chart w here the suction and discharge pressures cross. If "X" is below ambient temperature line, add charge and repeat step 3.8 Jun 2019 ... In This HVACR Training Video, I show How to Check the Refrigerant Charge and How to know what Target Subcooling to Set an Air Conditioner to ...Even if a system charge is available, you want to check superheat. And you want to check subcooling, more so as a reality check. 30ºF subcooling suggests to me that your orifice is too small. If we have data, let’s look at data. If all we have are opinions, let’s go with mine. – Jim Barksdale, former Netscape CEO.1. Take the low side pressure reading from your gauges and convert it to temperature using chart or gauge. 2. Then take the temperature of the Suction line as close to the condensing section as possible stay at least 6 inches from compressor. 3. Take the difference between the above readings (Suction line temp – Saturation temp) 4.*Red Italics Indicate Inches of Mercury Below Atmospheric Pressure Saturation Pressure-Temperature Data for R407C (psig)*Apr 15, 2019 · To determine the Target Superheat for an air conditioning system with a fixed orifice (such as a piston or capillary tube) measure the indoor WB (wet bulb) temperature with a digital psychrometer and the outdoor DB (dry bulb) temperature with a standard digital temperature reader. Input these temperatures in a superheat chart, calculation, app, or digital manifold set in order to determine the ... Superheat Charging Chart Cooling nonTXV R410A & R22. Preview. 8 hours ago Subcooling Charging Method - TXV (Expansion Valve) R410A & R22 Step 3 – subtract required subcooling (Step 1) from converted temperature (Step2) – This is the required liquid line temperature. Step 4 – Measure liquid line temperature.Bold (psig) = Saturated Liquid (calculate Subcooling) ⁰F Freon™ 22 (R-22) Opteon™ XP40 (R-449A) Freon™ MO29 (R-422D) Freon™ NU-22B™ (R-422B) Freon™ 407A (R-407A) Freon™ MO99™ (R-438A) Freon™ 407C (R-407C) Freon™ 410A (R-410A)-50-48-46-44-42 6.1 4.8 3.4 1.9 0.4 7.4 6.1 4.7 3.2 1.7 9.2 7.9 6.6 5.3 3.8 11.4 10.3 9.2 7.9 6.7 9 ...4) Actual line temperature should = chart temperature above. 5) If more than 5 degrees over, add charge to decrease line temperature. 6) If more than 5 degrees under, remove charge to increase line temperature. R22 TXV CHARGING CALCULATOR Based on 15 degrees sub-cooling Gauge Line Gauge Line Press. Temp. Press. Temp. 134 61 233 …21 Jan 2014 ... System Charging - R22, TXV, Low Charge ... How To Check Superheat & Subcooling On An HVAC System ... Charging Chart Basics. Ron Walker•47K views · 3 ...We will first examine the low-pressure side of the system, otherwise known as the vapor or suction line. During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG. If the system had R-22, the vapor pressure would be between 58 to 85 PSIG but these pressures will be dependent on ...Jul 27, 2020 · The best answer is—as usual—whatever the manufacturer says it should be. If you really NEED a general answer, you can generally expect: High Temp or A/C systems to run 6-14°F of superheat. Medium Temp – 5-10°F. Low Temp – 4-10°F. Some ice machines and other specialty refrigeration may be as low as 3°F of superheat. In today’s data-driven world, charts are an essential tool for visually representing information and making it easier to understand. Whether you’re a student, professional, or just...Generally, you will see normal superheat (8°-14°) on a system with heat mode TXV, and the subcooling will generally be a bit higher than usual, especially when measured outside. Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system.1. a) Most walk-in coolers and freezers use a TX valve to regulate the flow of refrigerant into the evaporator. If the superheat is low the TX valve will allow refrigerant to flow into the evaporator at a rate that exceeds the capacity of the evaporator and as a result liquid will enter the suction line.R-22 Superheat & Subcooling Calculator. This tool is used for charging cooling systems that use R-22 Refrigerant. One side of this tool is a slide chart used for calculating superheat for a NON-TXV system and the other side is a slide chart used to calculate subcooling on a TXV system.it must have a full line of properly subcooled liquid refrigerant all the way to the inlet. On a split system, checking the subcooling at the condensing unit is ...R-22 Superheat & Subcooling Calculator. This tool is used for charging cooling systems that use R-22 Refrigerant. One side of this tool is a slide chart used for calculating superheat for a NON-TXV system and the …Here is a table with these causes that will help us understand why we get low superheat normal subcooling: Low Superheat Causes: Non-Normal Subcooling Causes (High Or Low): Indoor airflow (CFMs) is too low. Oversized AC unit. Outdoor airflow is too low (or condenser coils heat exchange is impeded). High refrigerant charge (overcharged AC unit).R448a PT chart is quite useful in HVAC. It tells you what is the pressure of R488a liquid and vapor refrigerant from -49°F to 150°F.Inversely, you can also tell the temperature of R488a refrigerant if you know the pressures (from 0.7 psig to 462.8 psig).Technicians can use the Goodman Subcooling Chart to fine-tune these systems and address any potential problems. Conclusion Importance of Goodman Subcooling Chart. By now, you should have a solid understanding of the importance of the Goodman Subcooling Chart. It’s an invaluable tool that helps technicians: Enhancing System PerformanceWhen it comes to mailing letters and packages, it is important to know how much postage you need in order to ensure that your mail reaches its destination. One of the best ways to ...Our subcooling chart will help you understand subcooling levels for different refrigerants, making it easier to maintain your system… Subcooling Chart: Your Ultimate Guide to …The COP for R22, R410A and R32 are 2.33, 3.36 and 3.63, i.e. with compare to R410A and R22 the refrigerant R32 yields 7.34% and 36% higher COP. The refrigerant charge in to the vapour compression cycle was, for R22, R410A and R32 are 0.8 kg, 0.8 kg and 0.56 kg which determine the size of compressor.This 3D video shows setting a charge by subcool on a TXV system In 3D. Learn how to charge a TXV air conditioner or heat pump using the sub cooling method wi...Apr 8, 2020. 7 min read. The HVAC Subcooling Charging Method, Explained! Updated: Nov 20, 2023. In this article, we will define subcooling, calculate subcooling, explain …Theoretical comparison of refrigerating capacities over evaporating temperature in °C, relative to R22, at 40°C condensing, 10 K superheat, no subcooling Dew point and mid point temperature The refrigerants R448A,R449A, R407A, R407C, R407F, R417A, R422A, R422D, R427A, R438A change temperature during the evaporating or condensing … Subcooling = 100°F – 92°F = 8°F. The calculation itself is the easy part. The harder part is how to measure the needed refrigerant temperatures for superheat and subcooling calculation. We use an HVAC manifold gauge and a clamp-on thermometer for all superheat and subcooling measurements. Don't be fooled by an abridged chart with missing information, tidbits of random formulas and rule of thumb calculations all crammed on to one chart. The HVAC 3-Pack comes with 3 charts. One for sizing ductwork, one for calculating superheat/subcooling on R-22 systems and one for calculating superheat/subcooling on R-410a systems.Feb 15, 2014 · Subcooling is the amount of liquid held back in the condenser. This allows the liquid to give up more heat, below saturated pressure- temperature. For every one degree of subcooling at the same condensing+ pressure, capacity will increase .5 percent. See the chart that I developed for HVACPro app. R407c is an HFC refrigerant that will replace the R22 refrigerant, as per Montreal Protocol. It is a mixture of R32 (23%), R125 (25%), and R134a (52%) that has a boiling point of -46.84°F. The same as R22, due to useful pressure-temperature properties, R407c is used in air conditioning systems, cars, and refrigeration units. Below, you will ... Subcooling Charging Method - TXV (Expansion Valve) R410A & R22 Step 3 – subtract required subcooling (Step 1) from converted temperature (Step2) – This is the required liquid line temperature. Step 4 – Measure liquid line temperature. If the measured liquid line temperature does not equal the required liquid line temperature: Pressure Temperature Charts °F °C R-22 60 15.6 102 65 18.3 111 70 21.1 121 75 23.9 132 80 26.7 144 85 29.4 156 90 32.2 168 95 35.0 182 100 37.8 196 105 40.6 211 110 43.3 226 115 46.1 243 120 48.9 260 125 51.7 278 130 54.4 297 135 57.2 317 140 60.0 337 145 62.8 359 150 65.6 382 Vapor Pressure in PSIGApr 22, 2024 · The primary tool for measuring superheat and subcooling is a superheat/subcool meter or gauge, available from various brands in a price range of $70 to $250. Our research suggests looking for a gauge with presets for commonly used refrigerants like R22, R410a (Puron), R134a, and R404a to simplify the process. SuperCool Slide Rule. $19.99. Quantity. Add to Cart. PRODUCT INFO. SuperCool Slide Rule - R22 & R410a Charging & Duct Calculator - Air Conditioning and HVAC Troubleshooting, A/C Educational Products, & AC Charts - SuperHeat & SubCooling.

We will first examine the low-pressure side of the system, otherwise known as the vapor or suction line. During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG. If the system had R-22, the vapor pressure would be between 58 to 85 PSIG but these pressures will be dependent on .... Atlanta metro studios union city georgia

r22 subcooling chart

it must have a full line of properly subcooled liquid refrigerant all the way to the inlet. On a split system, checking the subcooling at the condensing unit is ...The R22 PT chart, or Pressure-Temperature chart, is used to determine the saturation temperature of R22 refrigerant at a specific pressure, and vice versa. It’s an essential tool for HVAC and refrigeration technicians to diagnose system issues, determine superheat and subcooling values, and correctly charge refrigeration systems.Subcooling Charging Method - TXV (Expansion Valve) R410A & R22 Step 3 – subtract required subcooling (Step 1) from converted temperature (Step2) – This is the required liquid line temperature. Step 4 – Measure liquid line temperature. ... Superheat Charging Chart - Cooling - non-TXV - R410A & R22 www.hvacsalesandsupply.com. Title ...STEP 2 - Remove the pressure tap cap and valve cores from both service valves. STEP 3 - Purge the refrigerant lines and indoor coil with dry nitrogen. STEP 4 - Wrap a wet rag around the valve body to avoid heat damage and continue the dry nitro-gen purge. Braze the refrigerant lines to the service valves.R22 chart superheat charging temperature curves line system orifice split liquid subcooling r410a cooling tables compressor metering txv device yorkR-134a / r-1234yf magnetic pressure temperature chart 8"x5.5" eur 9,96 Mua r22 superheat subcooling calculator charging chart trên amazon mỹChart r22 superheat subcooling …HVAC App to Calculate Superheat. Our Pressure Temperature Chart for the selected refrigerant is available for quick access; just use the button labeled (P/T). Use the refrigerant drop down for access to over 100 refrigerants. Plus and minus buttons add and subtract values in intervals of 1 to their related input fields.Apr 8, 2020 · Subcooling is a measurement of temperature DECREASE of a liquid below its saturation (mixed liquid/vapor) temperature at a given pressure. For example, water boils at 212° Fahrenheit at sea level (atmospheric pressure of 14.7 PSIA). If water is 212°F and at atmospheric pressure at sea level, you can be sure it is at saturation, which means it ... Subcooling is beneficial because it prevents the liquid refrigerant from changing to a gas before it gets to the evaporator. Pressure drops in the liquid piping and vertical risers can reduce the refrigerant pressure to the point where it will boil or "flash" in the liquid line. This change of phase causes the refrigerant to absorb heat before ...piston kit chart 4 ppkcg-4001j february 2015 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. for all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately.Since superheat doesn’t depend on the type of refrigerant we use, this chart can be used as target superheat chart for R-22, R-410A, R-134A, and all other freons. Here is the …24 May 2016 ... HVAC R22, 410A Refrigerants! Checking the Charge- Vapor/Suction Operating Pressures, What is Too Low! P/T Chart on the Manifold Gauge Set is ...The COP for R22, R410A and R32 are 2.33, 3.36 and 3.63, i.e. with compare to R410A and R22 the refrigerant R32 yields 7.34% and 36% higher COP. The refrigerant charge in to the vapour compression cycle was, for R22, R410A and R32 are 0.8 kg, 0.8 kg and 0.56 kg which determine the size of compressor.Have you ever wanted to create a flow chart in PowerPoint but didn’t know where to start? Look no further. In this step-by-step guide, we will walk you through the process of creat...In today’s data-driven world, charts are an essential tool for visually representing information and making it easier to understand. Whether you’re a student, professional, or just...According to the R-22 PT chart, this is equal to about 54°F. With the thermometer, we measured the saturated R-22 temperature of 45°F. Here is how we can calculate the R-22 superheat in this system: Superheat (R-22) = 54°F – 45°F = 9°F. The superheat calculator also gives us 9°F superheat for R-22 refrigerant.Up to 10% lower capacity. Lubricant Recommendation: Compatible with mineral and alkylbenzene oil and if oil return becomes a concern, addition of polyolester lubricant in 5% increments could help resolve the issue. Retrofitting to: R-422B for R-22 Air Conditioning page 95. R-422B for R-22 Refrigeration page 95..